16:00 - 18:00
Room: San Francisco
Poster session
Evaluation of transdermal drug-delivery system of capsaicin
Uzunovic Alija 1, Pilipovic Sasa 1, Sapcanin Aida 2, Ademovic Zahida 3
1 Agency for medicinal products and medical devices of Bosnia and Herzegovina, Sarajevo, Bosnia and Herzegovina
2 Faculty of Pharmacy, Sarajevo, Bosnia and Herzegovina
3 Faculty of Pharmacy, Tuzla, Bosnia and Herzegovina

Capsaicin has been employed topically to treat many diseases such as rheumatoid arthritis and nerve pain in diabetes. The short half-life of capsaicin by intravenous administration made topical application of capsaicin advantageous.

In this study, we have evaluated differences in the dissolution characteristics of capsaicin patch purchased from market, at different dissolution rotation speed.

The dissolution study was conducted using USP apparatus 5 (n=6), ERWEKA DT800 dissolution tester and 500 mL of pH 7.4 phosphate buffer as dissolution media. All dissolution studies were carried out at 32 ±0.50C and different rotation speed (50±5; 100±5 and 150±5 rpm). 5 ml aliquots of samples were withdrawn at various time intervals (1, 4, 8 and 12 hours). Withdrawn were appropriate diluted and analyzed by HPLC.

The HPLC method proposed by Al Othman et al. (2011) has been optimized and validated for the separation and quantitation of capsaicin in a transdermal patch [1].

HPLC analysis was performed using ProntoSIL 120-3-C18AQ 125x4,0 mm (3 μm) column maintained at 600C. The mobile phase consisted of acetonitrile: water (50:50v/v), the flow rate of 0.9 mL/min, the injection volume 10 μL and the detection wavelength 222 nm.

The used HPLC method can be applied for fast (total run time was 4.0 minutes) and simultaneous analysis of capsaicin and dihydrocapsaicin in a transdermal patch.

We can conclude that the relative difference of dissolution rate of capsaicin after 12 hours was elevated by increase of dissolution rotation speed (100 rpm vs 50 rpm: 87.1± 12.1% and 150 rpm vs 100 rpm: 39.6± 8.7%).

USP Apparatus 5 could be considered as a discriminatory test that would be able to point out the differences in the dissolution rate of capsaicin at different rotation speed.

Keywords: capsaicin, in vitro, HPLC, transdermal

References:

[1] Al Othman ZA et al. Molecules 2011; 16:8919-8929.


Reference:
Tu-Poster Session 2-PO-189:
Session:
Poster Session 2
Presenter/s:
Alija Uzunovic
Presentation type:
Poster presentation
Room:
San Francisco
Date:
Tuesday, 5th September, 2017
Time:
16:00 - 18:00
Session times:
16:00 - 18:00